How to specify a transfer switch for a residential or a light commercial application.

ASCO SERIES 185 Power Transfer Switches
For Residential or Light Commercial Use

image.pngimage.png


ASCO SERIES 185 Generator Transfer Switches reliably connect power from a backup generator to your home or business whenever outages occur. When utility power has been restored, this line of power transfer switches will automatically transfer your loads back to utility and shut down the generator, saving fuel and standing ready to address the next utility failure.

Features

  • User-friendly control interface with easy to understand symbols and visual indicators to inform operator of transfer switch and power source status.
  • Listed to UL 1008 for optional standby systems, handling total system load including motors and all other electrical loads.
  • cUL Listed for Canadian installations.
  • Available in 100 through 400A ratings.

Benefits

  • True double-throw contacts with inherent mechanical interlocking to prevent connection of generator and utility sources.
  • Terminals for convenient connection of neutral and ground conductors.
  • Working hand in hand with virtually every brand of generator, ASCO SERIES 185 Power Transfer Switches provide around-the-clock protection from a power failure, taking action only when required.
Technical and Ordering Information

image.png

image.pngNote:
Type 3R enclosures provide a degree of protection against falling dirt, rain, sleet, and snow.
Additional protection may be required in locations subject to wind blown conditions.

image.png
Notes:
  • All units are RMS Symmetrical Amperes
  • All Withstand and Closing Rating values are tested in accordance with UL 1008.
  • ASCO Publication 1128 for more information: https://download.schneider-electric.com/files?p_enDocType=Specification+guide&p_File_Name=1128_R29.pdf&p_Doc_Ref=TS-SP-1128ENGAPPINFO
  • Application requirements may permit higher WCR for certain switch sizes.
image.png
Notes:
UL listed for 200 amps with copper conductors only. For individual dwelling units as defined in NFPA 70 (NEC),
in cases where the transfer switch is between the service main disconnect and the lighting and appliance branch
circuit panelboard(s), NFPA 70 allows for a reductions in size of the feeder conductors. All other NFPA 70 requirements regarding conductor ampacities must also be observed. Always install electrical equipment to the requirements defined by the authority having jurisdiction.

Wiring and Outline Drawing Link:
  • https://www.ascopower.com/us/en/products/libraries/technical-documents/185-series/asco-series-185-power-transfer-switches-product-wiring-outline.jsp

Operator's Manual
  • https://www.ascopower.com/us/en/download/document/TS-UM-185ATS100400/